LONDON - Anteris Technologies reported on Nov. 22. Its investigational DurAVR transcatheter heart valve was studied. The valve kept one-year heart failure hospitalizations to 1%. It also showed zero valve-related deaths in a 100-patient study.
Biomimetic Valve Eases Blood Flow in Complex Patients
The pooled data came from U.S. and European feasibility trials. The patients had severe aortic stenosis. They also had small valve openings. That anatomy frequently leaves implants too tight for normal circulation.
After one year, the average pressure across the replacement valve dropped from 48.1 mmHg to 8.9 mmHg. The effective flow area expanded to 2.2 square centimeters. There was no moderate or severe leakage.
Activity limits improved. Patients experiencing mild or no daily activity limits rose from 39% before treatment to 96% at one year.
Cardiac MRI Shows Heart Muscle Recovery
One-year clinical safety events included a 6% all-cause mortality rate. The stroke rate was 3%. New permanent pacemakers occurred in 9% of recipients. 97% avoided moderate or severe valve sizing mismatch at 30 days.
A 64-patient MRI substudy was used. Enlarged left-ventricular heart muscle mass shrank by 24% over 12 months.
Cleveland Clinic cardiologist Rishi Puri spoke at the PCR London Valves conference. He said this. "While cross-trial comparisons should be interpreted with caution, what stands out to me is heart failure hospitalization of just 1% at one year," he said.
Head-to-Head Pivotal Trial Is Underway
DurAVR remains restricted to investigational use. It is not yet approved for commercial sale.
Anteris is actively enrolling roughly 1,000 patients. They are across the United States and Europe. They are in the randomized PARADIGM trial. It compares DurAVR directly against approved commercial heart valves.